3M ATP Fluorescence Detector,


1, the instrument is lightweight, weighing only 400 grams, easy to operate on site
2、Detector using photomultiplier tube The photomultiplier tube has the advantages of smaller size, sensitivity, speed and so on compared with the photodiode, which is suitable for more faint light.
3、Signal detection and reception, so that the real sensitivity can be achieved higher.
4、Detection range:0-999999RLU
5、Detection sensitivity up to 10-15mol ATP
6, can store 10000 test results
7, can store 100 sampling plan, each sampling plan can set up 300 sampling points
8、Can store 2000 planned sampling points
9、Multi-language operation interface, including Chinese Multi-language operation interface can be selected according to the actual needs of the customer base, in order to use the instrument to complete the detection process faster and more proficiently, as well as data analysis
10, the repeatability of the instrument detection, CV% value (coefficient of variation) is equal to 7.4% [see attached].
11, instrument reading time of 10 seconds
12, removable, rechargeable lithium battery, power to ensure continuous operation for 36 hours
13, The instrument displays the power balance and charging status.
14、Built-in power-on auto-check and alarm function
Power-on self-check function ensures that all components of ATP instrument are in normal working condition when power on.
Alarm function tells the customer that the instrument is in abnormal or abnormal working condition, so as to find out the problem as early as possible and solve the trouble.
15、Pixel liquid crystal display, the screen has a backlight function, the user can customise the duration of the backlight
16, the detection chamber / cover automatic sensing and alarm function Sampling rod into the instrument for testing, if not taken out in a timely manner, because of busy work is likely to forget the residual inside the sampling rod (especially the last one each time the test), then in the post-test shelf, if the instrument is placed on the level of the solution in the smear stick may leak into the chamber, resulting in contamination, causing the instrument to cause the light of the background value of the instrument to increase, or affect the impact of the optical components detection results, i.e., the failure of the machine, that is, the fault of the machine. This alarm function can warn the operator to take out the applicator at the end of the test, and at the same time to develop good operating habits.
17, you can download the self-edited inspection plan to the instrument, and then according to the plan for inspection.
18, the plan mode can be set up within the qualified limit, the instrument automatically determine the results of qualified and unqualified, and has a Retest function, re-cleaning after the test data directly with the test plan in this article
19, the instrument through the USB interface and computer links, supporting data trend analysis software can provide 9 kinds of results filtering mode, 5 kinds of report mode and 10 kinds of chart mode, automatically import the data into Excel tables
20、Can customise the user rights function
21、According to different enterprises in different locations recommended limit values [see attached].
22、Attached to the parameters of the sampling rod:
23, 3M Clean - Trace fluorescence sampling rod contains sufficient and stable liquid luciferin / luciferase, to overcome the shortcomings of the uneven reaction of freeze-dried enzyme preparations; and do not need additional reaction tube
24, The sample sticks maintain over 95% enzyme activity for 10 months (refrigerated).

STARS:
Catalogs for more options